The Catalyst Dx analyzer is part of the IDEXX VetLab* suite of analyzers, all of which connect to the. IDEXX VetLab Station (IDEXX’s laboratory information
76 pages

19 KB – 76 Pages

PAGE – 2 ============
2Proprietary rights notice Information in this document is subject to change without notice. Companies, names, and data used in examples are fictitious unless otherwise noted. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical, or otherwise, for any purpose, without the express written permission of IDEXX Laboratories. IDEXX Laboratories may have patents or pending patent applications, trademarks, copyrights, or other intellectual or industrial property rights covering this document or subject matter in this document. The furnishing of this document does not give a license to these property rights except as expressly provided in any written license agreement from IDEXX Laboratories.© 2020 IDEXX Laboratories, Inc. All rights reserved. Ł 06-0002387-08*IDEXX VetLab, Catalyst, Catalyst Dx, SNAP, 4Dx, VetTrol, and SmartService are trademarks or registered trademarks of IDEXX Laboratories, Inc. in the United States and/or other countries. All other product and company names and logos are trademarks of their respective holders.

PAGE – 3 ============
3ContentsPreface .5Safety Precautions 5International Symbol Descriptions 6Other Symbols 7Getting Started .8Introduction ..8Catalyst Dx Components ..9Installing the Catalyst Dx Analyzer .11Powering On the Analyzer .12Shutting Down the Analyzer..12Printing Test Results ..12Catalyst Dx Analyzer Consumables .13Compatible Species .14Using the Catalyst Dx* Analyzer .15Overview .15Using the Touch Screen ..15Analyzing Samples 15Diluting Samples .16Viewing Test Results 19Canceling a Run That Is In Process .19Removing a Sample from the Analyzer ..19Outside of Reportable Range Samples .20Modifying the Settings on the Analyzer .22Overview .22Changing the Language/Local Settings .22Deleting a Patient from the Pending and In Process Lists 23Sample Preparation and Storage ..24Supported Sample Types for Catalyst CLIPs and Slides ..24Preparing Samples for Use on the Catalyst Dx Analyzer ..25Proper Sample Cup Volume .27Sample Inspection After Centrifugation ..27Sample Storage ..28

PAGE – 4 ============
4Quality Control ..30Overview .30Quality Control Materials ..30Quality Control CLIPs and Slides ..31Preparing Control Fluid 32Running Quality Control ..33Maintenance ..35Overview .35Upgrading the Software..35Opening/Closing the Maintenance Access Doors 35Cleaning the Internal Components of the Analyzer ..36Cleaning the Fan Filter .38Cleaning the Centrifuge ..39Cleaning the Exterior of the Analyzer39Cleaning the Screen .40Emptying the Waste Drawer .40Troubleshooting 41Differences in Results ..41Status Messages 41Removing a Slide Jam .43Appendices .45Chemistry Descriptions ..45Medical Protocol Descriptions .70Technical Specifications .75IDEXX Technical Support Contact Information 76

PAGE – 5 ============
5PrefaceSafety Precautions The Catalyst Dx* Chemistry Analyzer weighs approximately 50 pounds (22 kg). It may require multiple people to lift the instrument. The analyzer does not contain any user-serviceable components. DO NOT disassemble. DO NOT stack other equipment or containers on top of the analyzer. Keep analyzer away from sources of heat or flames. DO NOT place or operate the analyzer near x-ray equipment, photocopiers, or other devices that generate static or magnetic fields. PROTECT your equipment from damp conditions or wet weather. Take care not to spill water or other fluids on the unit. DO NOT use any of the following liquids, abrasives, or aerosol sprays on, inside, or near the analyzer, as they may damage the analyzer and may influence results: Ł Organic solvents Ł Ammonia-based cleaners Ł Ink markers Ł Sprays containing volatile liquids Ł Insecticides Ł Disinfectant Ł Polish Ł Room freshener Ł Canned air Line voltage for the Catalyst Dx analyzer is 100Œ240 V AC, 50Œ60 Hz. Be sure to plug all equipment into properly grounded electrical outlets. Use only the power cable supplied. Disconnect the power cable: Ł If the cable becomes frayed or otherwise damaged. Ł If anything is spilled onto the equipment. Ł If your equipment is exposed to excessive moisture. Ł If your equipment is dropped or the case has been damaged. Ł If you suspect that your analyzer needs service or repair. Ł Whenever you clean the case. If the equipment is used in a manner other than specified, the protection provided by the equipment may be impaired.

PAGE – 6 ============
6International Symbol Descriptions International symbols are often used on packaging to provide a pictorial representation of particular information related to the product (such as expiration date, temperature limitations, batch code, etc.). IDEXX Laboratories has adopted the use of international symbols on our analyzers, product boxes, labels, inserts, and manuals in an effort to provide our users with easy-to-read information. Symbol Description Symbol Description Use by A utiliser avant Verwendbar bis Usare entro Usar antes de Temperature limitation Température limite Zulässiger Temperaturbereich Temperatura limite Limitación de temperatura Batch code (Lot) Code de lot (Lot) Chargenbezeichnung (Partie) Codice del lotto (partita) Código de lote (Lote) Upper limit of temperature Limite supérieure de température Temperaturobergrenze Limite superiore di temperatura Limite superior de temperatura Serial number Numéro de série Seriennummer Numero di serie Número de serie Consult instructions for use Consulter la notice d™utilisation Gebrauchsanweisung beachten Consultare le istruzioni per l™uso Consultar las instrucciones de uso Catalog number Numéro catalogue Bestellnummer Numero di catalogo Número de catálogo Keep away from sunlight Conserver à l™abri de la lumière Vor direkter Sonneneinstrahlung schützen Mantener alejado de la luz solar Tenere lontano dalla luce diretta del sole Authorized Representative in the European Community Représentant agréé pour la C.E.E. Autorisierte EG-Vertretung Rappresentante autorizzato nella Comunitá Europea Representante autorizado en la Comunidad Europea WEEE Directive 2002/96/EC Directive 2002/96/CE (DEEE) WEEE-Richtlinie 2002/96/EG Directiva 2002/96/CE RAEE Direttiva RAEE 2002/96/CE Manufacturer Fabricant Hersteller Ditta produttrice Fabricante Biological risks Risques biologiques Biogefährlich Rischi biologici Riesgos biológicos Caution, consult accompanying documents Attention, consulter les documents joints Achtung, Begleitdokumente beachten Attenzione, consultare la documentazione allegata Precaución, consultar la documentación adjunta 2Do not reuse Usage unique Nicht wiederverwenden No reutilizarw Non riutilizzare Preface

PAGE – 8 ============
8Getting StartedIntroduction Welcome to the Catalyst Dx* Chemistry Analyzer. The Catalyst Dx analyzer™s flexible test menu allows you to monitor the health status of specific organs, recheck values over time, customize profiles by adding single tests to CLIPs, and test blood and urine at the same time to uncover early renal disease (for a complete list of the individual slides and CLIPs available, see pages 13Œ14). You can even run up to 25 tests on a single sample. The analyzer™s touch-screen interface provides easy-to-follow instructions to help you navigate the system, enter patient data, specify testing information, and more. The Catalyst Dx analyzer is for veterinary use only. IDEXX VetLab* Station Connectivity The Catalyst Dx analyzer is part of the IDEXX VetLab* suite of analyzers, all of which connect to the IDEXX VetLab Station (IDEXX™s laboratory information management system). Connecting multiple analyzers to the IDEXX VetLab Station helps you attain a comprehensive picture of your patient™s health, with the ability to view test results from multiple analyzers on a single report, determine disease progression with parameter-trending capabilities, and more. By connecting the Catalyst Dx analyzer to the IDEXX VetLab Station, you can: Ł Automatically review patients™ prior results on every printout for easy comparison. Ł Improve client communications with illustrated diagnostic or treatment progress printouts. Ł Link to expert descriptions and common causes of abnormal values. Ł Print information to help explain the significance of results to your clients. Ł Allow new staff to train independently. Ł Learn proper protocols and tips for best techniques.

PAGE – 9 ============
9IDEXX Dry-Slide Technology The Catalyst Dx analyzer uses dry-slide technologyŠthe most accurate technology available for in-house testing. Dry-slide technology uses layers to minimize impurities for the most accurate results from even compromised samples. Patient sample is applied to the top of the spreading layerSpreading layer Sample is distributed evenly Reagent layer Reagent reacts with sampleSupport layer Optical interfaceIndicator layer Reacted sample collects for spectral analysisFiltering layer Minimizes substances that interfere with results How it Works There are several important steps that the analyzer performs in order to present the results of a sample. Once the slides and sample have been inserted into the analyzer, the Catalyst Dx analyzer incubates the slides and sample. Then, if using a Catalyst* whole blood separator, the plasma is separated from a whole blood sample. The sample is then accurately dispensed onto the slides, the analyzer measures the color development of the slide, and then all used materials are removed from the analyzer. Catalyst Dx Components Note: Some of the components on the Catalyst Dx analyzer have been redesigned since the analyzer was originally launched. The images in this section show the new hardware designs (for example, a single tip/diluent drawer). Getting Started

PAGE – 10 ============
10sample drawer assembly raise to gain access to the slide carousel and optics windowscentrifuge spins the whole blood separator to separate the whole bloodcenter latchpress to release/lift the sample drawer assembly and access the incubator ring, carousel, optics windows, etc.whole blood separator carrierstransport whole blood separators from the sample drawer to the centrifugepower switch use to turn on/off the analyzerEthernet port use to connect the analyzer tothe IDEXX VetLab Station power receptacle power cable plugs in hereBack of Catalyst Dx analyzerfan filtershould be cleaned quarterly (monthly if operated in dusty/dirty environment)Getting StartedUnderside of carouselwhite reference tile calibrates the chemistry optics module

PAGE – 11 ============
11Installing the Catalyst Dx Analyzer The Catalyst Dx analyzer works in conjunction with the IDEXX VetLab Station. To Install the Catalyst Dx Analyzer 1. Before you unpack the analyzer, choose an optimum location for the instrument. The analyzer should be placed on a level surface with a minimum of 2 inches (5 cm) between the back of the analyzer and any wall. Choose a well-ventilated area away from obvious sources of heat, direct sunlight, cold, humidity, or vibrations. For optimum results, room temperature should be at 15°CŒ30°C (59°FŒ86°F) and relative humidity at 15%Œ75%. IMPORTANT: Ensure proper ventilation. The analyzer™s cooling vents are in the base. Leave at least a 2-inch (5-cm) clearance around the machine so that air can circulate on all sides. 2. Unpack the analyzer. IMPORTANT: The analyzer weighs approximately 50 pounds (22 kg). It may require multiple people to lift the instrument. 3. Remove the packaging foam located inside of the open maintenance access doors. 4. Verify the two black whole blood separator carriers on the top of the sample drawer assembly are seated properly (flat) and in the left and right positions. 5. Verify the white centrifuge sleeve is in place to the right of the sample drawers. 6. Close the maintenance access doors (for detailed instructions, see fiOpening/Closing the Maintenance Access Doorsfl on pages 35Œ36). 7. Fill the tip drawer with pipette tips. 8. Ensure the Catalyst Dx analyzer is switched off and then connect the power cable to the analyzer and to a properly grounded electrical outlet. IMPORTANT: Do not power on the Catalyst Dx analyzer. After connecting the power cable, you must then connect to the router and to the IDEXX VetLab Station (instructions follow). To Install the IDEXX VetLab Station Connectivity Router Note: If you already have a network router connected directly to the IDEXX VetLab Station computer, you can skip this section and move to the fiTo Connect the Catalyst Dx Analyzer to the IDEXX VetLab Stationfl section (on the next page). 1. Connect the AC power adapter to the power port on the back of the network router supplied by IDEXX Laboratories. 2. Plug the AC power adapter into an electrical outlet. 3. Connect one end of the Ethernet cable (provided with the router) into any available port on the router. IMPORTANT : Do not connect the IDEXX VetLab Station directly to the Internet port on the router. 4. Connect the other end of the Ethernet cable (from step 3) into the IDEXX VetLab Station computer™s Ethernet port, which is located near the center panel on the back of the computer. Getting StartedEthernet port on the back panel of the IDEXX VetLab Station computer™s CPU

19 KB – 76 Pages

By redy